Our organization pays particular interest to customers’ needs, listening to the specific demands of each and every consumer and guaranteeing whole satisfaction. We are seeking forward to building effective organization interactions with new clients around the planet in the foreseeable future. In 2008, it was awarded with “National Export Commodity Inspection-free of charge Enterprise”. Application Scope:
JCEPBIO reg GUCS Sequence fermEPTTrs are ideal EPTs for exact fermentation experiment in microbiological laboratory for both universities, investigation cEPTTrs, institutes and personal EPTTrprises. It is generally utilized for tradition medium choice, fermentation method optimization and verification of strains as well as its production approach.
EPTnical Technical specs:
Design: GUCS-3, GUCS-5, GBUS-8
Complete Volume: 3L, 5L, 8L
Functioning volume: 2L, 3L, 5L
EPT: SS 316L / SS 304
Agitation: Flat-blade/indirect blade/curved blade/aXiHu (West EPT) Dis.al movement impeller for option
Type of JCEP: EPTic stirred from base
EPT Sort: EPTic coupling with out mechanical seal
Framework: Benchtop
Sterilization: Off-situ sterilized in an autoclave
EPTT Approach: EbioTM Info Aquisition and EPTT EPTT Technique mainly based on EPT PLC, exhibited and operated on vibrant touch EPT keep track of.? Particulars of Ebio handle technique
Characteristics:
The sterilizing operation is risk-free and reputable, and the tradition medium focus is exact soon after sterilization. It applies magnetic coupling to eliminate mechanical seal leakage threat. The fermEPTTr can be observed evidently, dismounted and mounted very easily, and operated conveniently.
Merchandise | Description |
---|---|
Design | GBCS-three/GBCS-five/GBCS-8 |
Whole Volume | 3L/5L/8L |
Functioning Quantity | 2L/3L/5L |
EPT | Borosilicate EPT vessel with stainless metal 316L top finish and base conclude |
Aeration | Glass rotameter and ring sparger, PALL .2um filter |
Agitation | Velocity adjustable: two hundred-800rpm plusmn1% |
Agitator | Two 6-blade Rushton impellers source as default |
JCEP | EPTic coupling stirred from bottom without mechanical seal |
Temperature | Pt-one hundred probe, automatic management |
pH | Mettler Toledo / HangEPTlton electrode, pH2.-twelve. plusmn0.1 |
DO | Mettler Toledo / HangEPTlton electrode, -a hundred% or -200% |
Antifoam | Sterilizable conductivity probe, computerized management |
Peristaltic poump | four peristaltic pumps assignable to purpose for acid, alkali, antifoam and feeding |
Structure | Benchtop |
Sterilization | Off-situ sterilized in an autoclave |
EPTT | EBio trade Information Aquisition and EPTT EPTT System mainly dependent on JCEP PLC, exhibited and operated on colorful contact EPT keep track of |
Optional | 1. MFC for areation 2. Multi-feeding three. Oxygen enrichment 4. Exhaust O2/CO2 examination 5. Weighing of feeding bottles 6. EPT agitator |